  Datasheet File OCR Text:
  technical data sheet for customer support or general questions please contact a local office or visit our website at www.marlow.com . doc # 102-0292 rev j - page 1 of 4 nl1013t single-stage thermoelectric module rohs eu compliant typical performance values mechanical characteristics [50.80+/-6.35] 2.00 +/-.25 (-) * (+) * [2.41 +/-0.13] .095+/-.005 [13.16] .518 [13.16] .518 a leads: 28 awg, buss, solid tinned copper ceramic material: alumina (ac) millimeters are in [ ] .005 [0.13] .001 [0.03] .001 [0.03] a * hot side, th -01ac, -02ac, -03ac cold side, tc * *note: cold side, hot side, positive leads, and negati ve leads are valid only for thermoelectric cooling. for power generation, refer to page 4. ordering options product features ? maximum operating temperature is 85c. ? maximum process temperature is 220c. ? ceramic material: aluminum oxide ? metallized exterior surfaces are au flash, suitable for soldering . ? rtv sealing options available . hot side temperature (c) 27c 50c ? tmax (c-dry vac): 61 69 qmax (watts): 4.8 5.4 imax (amps): 1.0 1.0 vmax (vdc): 8.5 9.6 ac resistance (ohms): 7.42 -- device zt 0.77 -- model number description nl1013t-01ac tem, top and base metallized exterior NL1013T-02AC tem, base metallized exterior nl1013t-03ac tem, no metallized exterior nl1013t-04ac tem, no metallized exterior, sealed, special wires
technical data sheet doc # 102-0292 rev j - page 2 of 4 *note: cold side, hot side, positive leads, and nega tive leads are valid only for thermoelectric cooling. for power generation, refer to page 4.
doc # 102-0292 rev j - page 3 of 4 typical performance curves environment: 10^-5 torr vacuum 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 (watts) load heat q=0 80 60 40 20 0 current (amps) 1.0 0.8 0.6 0.4 0.2 0.0 voltage (vdc) 8 6 4 2 0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 (watts) load heat q=0 80 60 40 20 0 current (amps) 1.0 0.8 0.6 0.4 0.2 0.0 voltage (vdc) 8 6 4 2 0 hot side temperature: 27c hot side temperature: 50c t=0 t (c) t=0 t (c) for performance information in nitrogen or with hot side temper atures other than 27c or 50c, contact one of our applications engineers at 877-627-5691. ? marlow reserves the right to make product changes without notice. installation recommended mounting methods: bonding with thermal epoxy or soldering with metallized ceramics. for additional information, please refer to our tec installation guide. operation cautions for maximum reliability, storage and operation below 85c in a non- condensing environment is recommended. to minimize thermal stress, use linear/proportional temperature control or a similar method rather than an on/off method. contact us: for customer support or general qu estions please contact a local office below or visit our website at www.marlow.com . marlow industries, inc. 10451 vista park road dallas texas 75238-1645 214-340-4900 (tel) 214-341-5212 (fax) 877-627-5691 (tech support) www.marlow.com marlow industries europe gmbh brunnenweg 19-21 64331 weiterstadt germany tel.: +49 (0) 6150 5439 - 403 fax: +49 (0) 6150 5439 - 400 info@marlow-europe.eu ii-vi japan inc. wbg marive east 17f 2-6 nakase, mihama-ku chiba-shi, chiba 261-7117 japan 81 43 297 2693 (tel) 81 43 297 3003 (fax) center@ii-vi.co.jp www.ii-vi.co. jp ii-vi singapore pte., ltd. blk. 5012, techplace ii #04-07 & 05-07/12, ang mo kio ave. 5 singapore 569876 (65) 6481 8215 (tel) (65) 6481 8702 (fax) info@ii-vi.com.sg www.ii-vi.com.sg marlow industries china, ii-vi technologies beijing a subsidiary of ii-vi incorporated rm 202, 1# lize 2nd middle road wangjing, chaoyang district beijing 100102 china 010-64398226 ext 105 (tel) 010-64399315 (fax) info@iivib j .com
doc # 102-0292 rev j - page 4 of 4 typical performance curves power generation performance information is given in a nitrogen environment and cold side temperatures of 27c and 50c. modul e temperature does not include thermal resistance of heat sink s. for performance information in vacuum, other cold side temperatures, or specific heat sinks, co nsult one of our applications engineers. typical power generation configuration example: (+) (-) hot side, th cold side, tc 30 35 40 45 50 55 65 75 85 0 0.2 0.4 0.6 0.8 1 1.2 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.20.71.21.72.22.73.2 opt voltage (v) opt power (w) heat (w) hot side temperature (c) power voltage t c =27c 55 60 65 70 75 80 85 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 opt voltage (v) opt power (w) heat (w) hot side temperature (c) power voltage t c =50c 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 012345678910 voltage / voc / opt load resistance ratio normalized off-peak performance efficiency voltage hot side temperature (c) 85 55 35 cold side temperature (c) 27 27 27 optimum efficiency, (%) 2.52 1.28 0.37 optimum power (w) 0.087 0.021 0.002 optimum voltage (v) 1.021 0.487 0.138 load resistance for opt ( ? ) 12.00 11.20 10.65 open circuit voltage, voc (v) 1.79 0.85 0.24 short circuit current (a) 0.20 0.10 0.03 thermal resistance (c/w) 16.86 16.88 16.85


▲Up To Search▲   

 
Price & Availability of NL1013T-02AC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X